Used by ABL on it's crushing plants, built by MINYU at their works in Taiwan, are shown as alternative for the Andean Region and Caribbean markets, offering the highest level performance and a convenient low price. More than 4000 sold and working since 1966, more than 700 working in the Americas show their excellent relation between investment and product in the market. Designed to produce and last, use hydraulic relief and adjustment system that permit the resetting with a shorter production stop. The external lubrication unit will maintain stable oil supply to the machine for smooth rotation by forced lubrication ; easy wearing parts replacement, low replacement parts price and commercial bearings use will ease service and maximize the results.

|
Capacities in TPH for each model and it's output setting
Nota 1 |
Effective square opening on closed circuit screen, mm |
|
6 |
10 |
13 |
16 |
9 |
22 |
15 |
38 |
51 |
64 |
Nota 2 |
Recommended closed side setting for closed circuit operation, mm |
Size |
Model No. |
6 |
10 |
10 |
13 |
16 |
19 |
19 |
25 |
32 |
38 |
600mm |
MCC24 |
|
12~24 |
16~28 |
20~30 |
24~35 |
28~40 |
32~42 |
48~58 |
|
|
(2ft) |
MCF24 |
10~20 |
12~24 |
16~28 |
20~30 |
24~35 |
28~40 |
32~42 |
48~58 |
|
|
900mm |
MCC36 |
|
|
|
45~75 |
60~90 |
75~110 |
85~110 |
120~150 |
145~170 |
|
(3ft) |
MCF36 |
|
35~65 |
40~70 |
45~75 |
60~90 |
70~105 |
80~105 |
120~150 |
145~170 |
|
|
MCSH36 |
35~70 |
40~80 |
48~80 |
57~97 |
65~120 |
80~130 |
|
|
|
|
1000mm |
MCC40 |
|
|
|
60~90 |
75~110 |
100~150 |
110~150 |
150~185 |
170~205 |
|
(3 ¼ft) |
MCF40 |
|
45~80 |
50~80 |
60~90 |
75~110 |
75~130 |
100~135 |
125~175 |
|
|
|
MCSH40 |
40~75 |
55~85 |
60~85 |
80~110 |
90~140 |
110~180 |
|
|
|
|
1200mm |
MCC48 |
|
|
|
|
100~145 |
115~175 |
130~180 |
170~210 |
195~235 |
|
(4ft) |
MCF48 |
|
50~95 |
55~95 |
70~105 |
85~125 |
100~150 |
120~155 |
165~200 |
|
|
|
MCSH48 |
|
65~95 |
70~95 |
90~130 |
105~160 |
125~190 |
|
|
|
|
1300mm |
MCC51 |
|
|
|
|
120~175 |
130~200 |
150~205 |
195~240 |
225~270 |
|
(4 ¼ft) |
MCF51 |
|
|
|
80~120 |
95~155 |
130~170 |
140~180 |
185~230 |
215~260 |
|
|
MCSH51 |
|
75~120 |
80~120 |
100~150 |
130~185 |
140~220 |
|
|
|
|
1370mm |
MCC54 |
|
|
|
|
|
150~225 |
170~230 |
220~270 |
250~305 |
|
(4 ½ft) |
MCF54 |
|
|
|
90~135 |
110~160 |
130~195 |
155~200 |
215~260 |
|
|
|
MCSH54 |
|
85~130 |
90~130 |
115~170 |
135~210 |
160~250 |
|
|
|
|
1500mm |
MCC6 |
|
|
|
|
|
180~265 |
200~270 |
260~320 |
300~360 |
|
(5ft) |
MCF6 |
|
|
|
|
130~190 |
155~225 |
185~240 |
255~310 |
|
|
|
MCSH6 |
|
100~160 |
105~165 |
135~200 |
160~250 |
190~295 |
|
|
|
|
1600mm |
MCC63 |
|
|
|
|
|
215~310 |
235~315 |
305~380 |
360~425 |
|
(5 ¼ft) |
MCF63 |
|
|
|
|
150~225 |
185~250 |
220~290 |
300~370 |
|
|
|
MCSH63 |
|
115~190 |
125~190 |
160~235 |
190~280 |
225~330 |
|
|
|
|
1680mm |
MCC66 |
|
|
|
|
|
|
|
325~400 |
375~450 |
400~525 |
(5 ½ft) |
MCF66 |
|
|
|
|
160~240 |
195~280 |
230~300 |
320~390 |
|
|
|
MCSH66 |
|
125~200 |
130~200 |
180~270 |
235~315 |
255~360 |
|
|
|
|
Capacity in tons( 2,000 lbs )per hour bases on closed and open circuit operations of continuous feeding of clean and dry materials with a bulk density of 1.60ton/cbm. Capacity may vary plus or minus 25% on operating conditions such as method of feeding, the weight, cleanliness and moisture contents of the material and its fracture pattern...etc. |
Note 1 |
Recommended closed side setting for closed circuit operation, mm |
Note 2 |
Size |
Model No. |
6 |
10 |
13 |
16 |
19 |
22 |
25 |
38 |
51 |
64 |
600mm |
MCC24 |
|
20 |
25 |
30 |
35 |
45 |
50 |
75 |
|
|
(2ft) |
MCF24 |
18 |
20 |
25 |
30 |
35 |
40 |
45 |
60 |
|
|
900mm |
MCC36 |
|
|
65 |
80 |
100 |
120 |
130 |
180 |
|
|
(3ft) |
MCF36 |
|
50 |
65 |
80 |
90 |
100 |
|
|
|
|
|
MCSH36 |
60 |
75 |
90 |
105 |
120 |
|
|
|
|
|
1000mm |
MCC40 |
|
|
80 |
100 |
135 |
150 |
175 |
235 |
300 |
|
(3 ¼ft) |
MCF40 |
|
65 |
75 |
90 |
120 |
135 |
150 |
|
|
|
|
MCSH40 |
65 |
80 |
100 |
125 |
140 |
|
|
|
|
|
1200mm |
MCC48 |
|
|
135 |
155 |
170 |
200 |
270 |
340 |
|
|
(4ft) |
MCF48 |
|
70 |
100 |
120 |
140 |
155 |
170 |
|
|
|
|
MCSH48 |
65 |
80 |
100 |
125 |
140 |
|
|
|
|
|
1300mm |
MCC51 |
|
|
|
150 |
180 |
195 |
230 |
310 |
390 |
|
(4 ¼ft) |
MCF51 |
|
|
115 |
140 |
160 |
180 |
210 |
|
|
|
|
MCSH51 |
|
110 |
130 |
170 |
185 |
|
|
|
|
|
1370mm |
MCC54 |
|
|
|
|
200 |
220 |
260 |
350 |
440 |
|
(4 ½ft) |
MCF54 |
|
|
130 |
155 |
180 |
200 |
220 |
|
|
|
|
MCSH54 |
|
125 |
150 |
190 |
210 |
|
|
|
|
|
1500mm |
MCC6 |
|
|
|
|
240 |
265 |
310 |
420 |
525 |
580 |
(5ft) |
MCF60 |
|
|
|
185 |
215 |
240 |
265 |
|
|
|
|
MCSH60 |
|
150 |
180 |
210 |
235 |
|
|
|
|
|
1600mm |
MCC63 |
|
|
|
|
265 |
320 |
370 |
500 |
625 |
655 |
(5 ¼ft) |
MCF63 |
|
|
220 |
240 |
290 |
320 |
|
|
|
|
|
MCSH63 |
|
170 |
205 |
245 |
310 |
|
|
|
|
|
1680mm |
MCC66 |
|
|
|
|
|
330 |
390 |
525 |
655 |
725 |
(5 ½ft) |
MCF66 |
|
|
|
230 |
270 |
300 |
330 |
|
|
|
|
MCSH66 |
|
185 |
225 |
265 |
340 |
|
|
|
|
|
Capacity in tons( 2,000 lbs )per hour bases on closed and open circuit operations of continuous feeding of clean and dry materials with a bulk density of 1.60ton/cbm. Capacity may vary plus or minus 25% on operating conditions such as method of feeding, the weight, cleanliness and moisture contents of the material and its fracture pattern...etc. |
|